Changes in AS3600:2018 Amendment 2 (Concrete)
Changes in AS3600:2018 Amendment 2 (Concrete)
Background
A number of significant updates have been made with AS3600:2018 Amdt 2, whose key effects are on the spacing and quantity of shear fitments / ligatures required. ClearCalcs has updated its calculator for consistency with this new amendment.
ClearCalc’s concrete calculators affected by Amendment 2 changes are:
- L-Type Cantilever Retaining Wall
- Rectangular Concrete Beam
- Rectangular Concrete Column
- Concrete Pad Footing
- One-Way Concrete Flat Slab
- Concrete Wall Footing
Capacity Reduction Factor (Bending Moment with compression)
- Table 2.2.2 (d) has changed the Φ0 factor to be equivalent to
math 0.65 \times k_\Phi
. There is a minor impact on the reduction factor where columns are slender or wheremath Q/G \leq 0.25
, refer to calculations formath k_\Phi
.
Shear Strength
-
Upper limit shear strength (
math V_{u,max}
) has been reduced by 10% in equation 8.2.3.3(1) -
Factor kv (simplified method) increases the concrete shear capacity (
math V_{uc}
) by up to 50% from Amendment 1, in particular for thinner depth sections without reinforcement. Previously a limit ofmath k_v = 0.10
was placed for any beam where minimum shear reinforcement was not satisfied or no fitments were provided. This has now been increased tomath k_v = 0.15
. Refer Cl 8.2.4.3(a)
Fitment Detailing / Spacing requirements
-
The minimum reinforcement spacing is now relaxed for beams with low shear force. Where
math V^* \leq \Phi V_{u,min}
, the fitments may now be spaced at 500mm ormath 0.75 \times D
, whereas previously 300mm ormath 0.5 \times D
limit was imposed under all circumstances apart from very large beams. -
For a short column satisfying,
math L < 5 \times \text{depth}
, Amendment 2 has introduced minor changes to the max allowable fitment spacing to reflect the actual fitment strength.math \text{spacing} = \sqrt{(f_{syf}/500)} \times 24 \times d
instead ofmath \text{spacing} = 24 \times d
previously in accordance with Cl 14.5.4(b) -
For beams of
math \text{depth} > 300\text{mm}
, shear fitments are now required even whenmath V^*
does not exceedmath \Phi V_{uc}
. An additional factormath k_s
has been added factoring down the upper limit shear force that may be taken without adding fitments in Eq Cl 8.2.1.6(1).
Renaming of Variables
7. math D_c
now renamed to math b
(smaller column cross-sectional dimensions). Refer Cl 1.7.
8. math K_s
now renamed to math k_s
(Beam Depth Factor to Determine Reinforcement Required). The definition of math K_s
in Cl 1.7 has not been updated in Amendment 2 from its previous version. It is believed that this definition should be further expanded in future revisions to reflect its use in Cl 8.2.1.6(1).
Assumptions
- The above is not a comprehensive list of Amendment 2 changes. However, they do reflect all the changes that are relevant to calculations performed in ClearCalcs.
- ClearCalcs concrete calculators utilise the Simplified Method for calculating
math k_v
andmath \theta_v
in compliance with Cl 8.2.4.1. Therefore the Amendment 2 updates for the “General Method” Cl 8.2.4.2 are not listed above.