The ClearCalcs Bushfire Attack Level calculator allows the user to quickly find the BAL for any site in Australia with just five simple inputs, using both the simplified method and the detailed method (AS3959: Appendix B) simultaneously.
Signing up for a ClearCalcs account will unlock further advanced features for design and analysis of beams and a variety of other structural elements. ClearCalcs enables design in steel, concrete and timber, according to Australian, US and EU Standards.
The sheet is divided into four main sections:
1. Key Properties, where all of the required inputs are entered. 2. Advanced Parameter Overrides, where advanced users may enter overrides for values used in the detailed (Appendix B) method, such as ambient temperature, flame width and emissivity, and elevation of the receiver. 3. Summary, where the calculated Bushfire Attack Level is displayed, along with information about the design considerations that the given BAL requires. If a simplified method calculation is valid, then maximum distances to the vegetation for each BAL are also shown in tabular form. 4. Detailed Method Results, where calculated values of interest to advanced users are displayed, including the forward rate of speed, flame angle, view factor, and radiant heat flux.
A ‘Comments’ section is also included for the user to leave any specific design notes. Clicking on any of the input/property labels gives a descriptive reference explanation.
Only five key inputs are required for most Bushfire Attack Level calculations.
In the simplified method, the slope between the site and the vegetation, referred to as the Site Slope, is assumed to be the same as the Effective Slope Under the Classified Vegetation. If this is not the case, however, then the Site Slope may also be changed in this section, and will affect the results of the detailed (Appendix B) method.
Most users can simply ignore this section, though advanced users may wish to override various parameters of the detailed (Appendix B) method calculations. Please refer to the descriptions for each value and/or the AS 3959 clause cited for each override for details on what exactly each means. Changing any of these values will result in the simplified method no longer being valid,and the associated results disappearing from the Summary section on the right side of the page. Clearing an input box will result in the default simplified method value being used for the parameter.
If applicable, results from the simplified method are displayed first - with the most important value, the Bushfire Attack Level by Simplified Calculation displayed at the top of this section. A Bushfire Attack Level Distances by Simplified Calculation table then follows this value, showing the distances from the classified vegetation at which that BAL classification will change. Note that these pieces of information will not be displayed if the simplified method is not valid (such as if a custom FDI was used, or if any of the Advanced Parameter Overrides were set).
Bushfire Attack Level by Detailed Calculation: The BAL calculated by the detailed (Appendix B) method will be displayed below the simplified method results. In most cases, this will match with the simplified method result, though may differ in particular if the Site Slope is changed.
Applicable Construction Requirements Sections in AS 3959:2018: The important results of a BAL classification are the construction requirements sections that are triggered. Therefore, the section numbers required by the calculated BAL are shown following the actual BAL, along with the standard's Description of Predicted Bushfire Attack which can occur at the calculated BAL.
Below the Summary, advanced users may click on the Detailed Method Results heading to see the results for the Appendix B calculations performed. These results include the following:
Chat with our Customer Success team and get product or account support directly to your inbox.