(Note: The New Zealand Steel Column module also refers to this article. While New Zealand uses a different standard - NZS 3404.1:1997 - it is substantially similar to the Australian standard, and so this article is almost entirely applicable)
The ClearCalcs Steel Column Calculator allows users to design steel columns by specifying the desired load cases and dimensions of the column. In this article, each section of the calculator will be explained followed by a few worked examples.
The Steel Column Calculator has 4 main sections
1. Key Properties 2. Design Criteria 3. Loads 4. Summary and Graphs
ClearCalcs gives the user the opportunity to use a custom member size if they wish. If 'no' is selected for the use of custom members, the user is provided with a drop-down list industry-standard size members from which a member can be selected.
Alternatively, the member selector and autosize functions (circled in red in the above diagram) can also be used to select a member.
The total height of the column needs to be given In millimetres (mm).
The first column of this table refers to the bracing type, which is of 3 categories. Torsional bracing restricts movement about the z-axis, while x-axis and y-axis lateral bracing restricts movement about the x and y-axes respectively. The orientation of the axes is given by the diagram on the left.
The second column requires the user to input the unbraced length in mm for each of the bracing types. By default, this is set equal to the column height. However, if additional bracing is used, the unbraced length will be smaller than the column height. It may be useful to enter user formulas for these unbraced lengths, such as "L/2" if the column is braced at mid-height.
The third column is allocated for the effective length factor, which by default is assumed to be equal to 1; this is usually conservative, and is equal to assuming pin-type restraints. However, if the column's restraints provide moment restraint (analogous to a fixed restraint), then this factor may be lower.
Effective Unbraced Length = Unbraced Length x Effective Length Factor
This section prompts the user to select the support type from a drop-down menu and then specify the location of each support in millimetres(mm) as measured from the bottom of the column. The user then has to specify the restrain type of each support entered. A diagram of what is meant by the Full, Partial, and Lateral restraint types is available in the description if this field is expanded.
In this section, the user can choose between a braced frame and a sway frame for their design. In a sway frame, the structure as a whole is allowed to sway laterally while in a braced frame such movement is effectively restrained. See AS 4100:1998, Cl 4.1.2 for a more detailed definition.
Deflection Limit Absolute Criterion: This is the hard maximum deflection allowed for the column, regardless of span length, and applied to all load cases.
Extension Limit Absolute Criterion: This is the hard maximum extension allowed for the column.
To enter an axial, point or moment load, one needs to fill out the above table. The first column refers to the name of the load, which can be decided by the user. Then the location at which the load acts on the column as measured from the bottom of the column (in millimetres) needs to be entered.
The third column refers to the axial eccentricity of the load; this is set according to the "Default Axial Load Eccentricity" by default. Axial eccentricity will be discussed in detail in part C of this section. When one clicks on the fourth column the following table will appear.
In this table, the user can select the load type from the drop-down menu shown, and specify the magnitude of the load in the x and y directions in kilo Newtons(kN) and enter any moment loads in kilo Newton Metres(kNm).
This table is applicable to distributed loads that act in the x-direction (i.e. perpendicular to the column). Similar to the Point Loads table, the first column of the lateral distributed loads table prompts the user to name the load. Then the start and end location of the distributed load must be specified, as measured from the bottom of the column. Then the start and end width of the load must be entered in millimetres(mm). To enter the load magnitudes, the following table must be filled out.
The load type must be selected from the drop-down menu in the first column, then the load magnitude must be specified per area in units of kilo Pascals(kPa).
What is Axial Load Eccentricity?
Generally, axial loads (i.e. loads acting vertically downwards) act through the centre of a column. However, in some cases, the load can act off the centre of the column and cause bending in addition to compression of the column. Axial load eccentricity refers to the horizontal distance between the centre of the column and the line of action of the axial load.
Axial Load Eccentricity Options in ClearCalcs
The user can choose whether or not they include the self-weight of the column in their calculations. The calculator is set to include the self-weight by default unless the user specifies otherwise.
The character of imposed loads that is most applicable to the intended use of the column can be selected from this drop-down menu.
The summary section the key parameters of your calculation will be outlined.
In the graphs section, the user can select whether or not they include the load duration factor k1 in the plots and select the load case that they would like the see in their graph (e.g.: 1.2G 1.5Q). The user can also specify whether they want the axial compression capacity graphed on the plot.
A sample of the summary and graphs produced during calculations can be seen in the examples given below.
Design a steel stud with the following characteristics
Access the full PDF file here: Task 1
Chat with our Customer Success team and get product or account support directly to your inbox.